HENRY泄压阀5232A-20.7BAR-CE参数介绍
HENRY泄压阀介绍
The function of a Pressure Relief Valve is to protect against over-pressure. For safety reasons, excessive over-pressure in any part of the refrigeration system must be avoided
Applications
A typical application for a Henry Technologies pressure relief valve (PRV) is to protect a liquid receiver from being over-pressurised. In the event of a fire, any liquid refrigerant inside the receiver will evaporate resulting in an increase in pressure. The PRV will safely control this increase in pressure by venting the vapour from the receiver. Another application is to protect equipment from compressor over-pressure.
Henry Technologies pressure relief valves are designed to discharge vapour and should not be used to vent liquid refrigerant. The valves are “back-pressure dependent” and are therefore required to discharge to atmosphere.
The brass and stainless steel series valves are suitable for use with HCFC and HFC refrigerant gases. The stainless steel series valves are also suitable for ammonia.
Once a PRV has discharged, replacement is recommended, as the set pressure can no longer be guaranteed. Refer to Installation Section for further information.
In line with the Institute of Refrigeration Guidelines (UK), Henry Technologies recommend that a PRV should be replaced at least every 5 years. These intervals may have to be reduced if other regulations apply.
It is recommended to have a relief valve pressure setting at least 25% higher than the maximum system operating pressure. The PRV set pressure should not be higher than the design pressure (MWP) of the vessel.
泄压阀的功能是防止过压。 出于安全原因,必须避免制冷系统任何部分的压力过高
应用领域
Henry Technologies 泄压阀 (PRV) 的典型应用是保护液体接收器免遭过压。 如果发生火灾,接收器内的任何液体制冷剂都会蒸发,导致压力增加。 PRV 将通过从接收器排出蒸汽来安全地控制压力的增加。 另一个应用是保护设备免受压缩机过压的影响。
Henry Technologies 泄压阀设计用于排放蒸汽,不得用于排放液体制冷剂。 这些阀门是“背压相关的”,因此需要排放到大气中。
黄铜和不锈钢系列阀门适用于 HCFC 和 HFC 制冷剂气体。不锈钢系列阀门也适用于氨。
一旦减压阀泄压,建议更换,因为无法再设定压力。请参阅安装部分了解更多信息。
根据英国制冷协会指南,Henry Technologies 建议至少每5年更换一次PRV。 如果其他规定适用,这些间隔可能必须缩短。
建议安全阀压力设置至少比*大系统工作压力高 25%。PRV设定压力不应高于容器的设计压力(MWP)。
HENRY泄压阀523系列其他常用型号:
5230A-20.7BAR-CE
5231A-20.7BAR-CE
5231B-20.7BAR-CE
5232A-20.7BAR-CE
5240-20.7BAR-CE
5242-20.7BAR-CE
5244-20.7BAR-CE
5246-20.7BAR-CE
HENRY Pressure Relief Valves NEW + ORIGINAL+ ONE YEAR WARRANTY
爱泽工业成立于2010年,定位于向制造工业提供高端制造技术和设备。代理经营世界优质的电气自动化、机械与传动、流体控制、仪器仪表、工具等产品。作为电气,液压以及气动解决方案的合作伙伴,我们利用我们的全球协作团队,为客户提供先进解决方案,市场知识以及相关增值服务来帮助优化客户的工作效率,提高可靠性和安全性,致力于成为工业产品和解决方案的优质渠道。
如果有任何关于
HENRY泄压阀5232A-20.7BAR-CE的疑问,请随时与我们沟通( )。我们将尽全力解决您的问题。
If you have any question for
HENRY products, please feel free to dial 0086-21-3100 6702/ send request email to / browse our website:www.ize-industries.com.
HENRY泄压阀5232A-20.7BAR-CE介绍